Spygen
mySPYGEN

Login zone

Detecting Legionella directly from water samples using eDNA

A group of researchers assessed whether qPCR assays can be conducted from 1L water samples to identify or rule out sources of Legionella.

In August 2015, Collins et al. published a paper entitled “Real-time PCR to supplement gold-standard culture-based detection of Legionella in environmental samples” in the “Journal of Applied Microbiology”.

Summary:

Aims
Culture remains the gold-standard for the enumeration of environmental Legionella. However, it has several drawbacks including long incubation and poor sensitivity, causing delays in response times to outbreaks of Legionnaires’ disease. This study aimed to validate real-time PCR assays to quantify Legionella species (ssrA gene), Legionella pneumophila (mip gene) and L. pneumophila serogroup-1 (wzm gene) to support culture-based detection in a frontline public health laboratory.

Methods and Results
Each qPCR assay had 100% specificity, excellent sensitivity (5 GU/reaction) and reproducibility. Comparison of the assays to culture-based enumeration of Legionella from 200 environmental samples showed that they had a negative predictive value of 100%. Thirty eight samples were positive for Legionella species by culture and qPCR. One hundred samples were negative by both methods whereas 62 samples were negative by culture but positive by qPCR. The average log10 increase between culture and qPCR for Legionella spp. and L. pneumophila was 0.72 (p = 0.0002) and 0.51 (p = 0.006) respectively.

Conclusions
The qPCR assays can be conducted on the same 1L water sample as culture thus can be used as a supplementary technique to screen out negative samples and allow more rapid indication of positive samples.

Significance and impact of the study
The assay could prove informative in public health investigations to identify or rule out sources of Legionella as well as to specifically identify L. pneumophila serogroup 1 in a timely manner not possible with culture.


Reference
: Collins, S., Jorgensen, F., Wills, C., Walker, J. (2015). Real-time PCR to supplement gold-standard culture-based detection of Legionella in environmental samples. Journal of Applied Microbiology. DOI: 10.1111/jam.12911.